Leading Manufacturers, Exporters and Wholesaler of Grd 4 Grad Mobile High Frequency, Grd 8 Grad Mobile High Frequency, Grd 15 Grad Mobile High Frequency and Grd 20 Grad Mobile High Frequency from Gautam Buddha Nagar.
| Business Type | Manufacturer, Exporter, Supplier |
| Model | GRD 4 |
| X Ray Generator | High Frequency 40Khz/ 200Khz |
| Output Power | 4.0 KW |
| Rad. KV | 40-100kV |
| Rad. MA | Upto 100 MA |
| Mas Range | 1 To 200mAs |
| Control Panel | Totally Feather Touch Micro Controller Based |
| Digital Display | KV And MAs |
| Interlocks | Earth Fault, Voltage Error, Rotor Error, KV Error, Fillament Error & Thermal Protection |
| Dual Action Hand Switch With Retractable Cord | Provided |
| X-Ray Tube Head | Monoblock Version |
| X-Ray Tube | Stationary / Rotating Anode |
| Collimator | Manaul/Auto/Multi Lead Operated With Beam Diaphragm |
| Tube Stand | Spring Balance/ Counter Balance Mobile (CBM) |
| Power Supply | 230v, AC, Sinngle Phase +-10% 50Hz |
It seems like you have provided a set of statements related to X-ray technology. Here is an explanation of what each statement means:
| Business Type | Manufacturer, Exporter, Supplier |
| Model | GRD 8 |
| X Ray Generator | High Frequency 40Khz/ 200Khz |
| Output Power | 8.0 KW |
| Rad. KV | 40-120kV |
| Rad. MA | Upto 150 MA |
| Mas Range | 1 To 200mAs |
| Control Panel | Totally Feather Touch Micro Controller Based |
| Digital Display | KV And MAs |
| Interlocks | Earth Fault, Voltage Error, Rotor Error, KV Error, Fillament Error & Thermal Protection |
| Dual Action Hand Switch With Retractable Cord | Provided |
| X-Ray Tube Head | Monoblock Version |
| X-Ray Tube | Stationary / Rotating Anode |
| Collimator | Manaul/Auto/Multi Lead Operated With Beam Diaphragm |
| Tube Stand | Spring Balance/ Counter Balance Mobile (CBM) |
| Power Supply | 230v, AC, Sinngle Phase +-10% 50Hz |
It seems like you have provided a set of statements related to X-ray technology. Here is an explanation of what each statement means:
| Business Type | Manufacturer, Exporter, Supplier |
| Model | GRD 15 |
| X Ray Generator | High Frequency 40Khz/ 200Khz |
| Output Power | 15.0 KW |
| Rad. KV | 40-125kV |
| Rad. MA | Upto 250 MA |
| Mas Range | 1 To 200mAs |
| Control Panel | Totally Feather Touch Micro Controller Based |
| Digital Display | KV And MAs |
| Interlocks | Earth Fault, Voltage Error, Rotor Error, KV Error, Fillament Error & Thermal Protection |
| Dual Action Hand Switch With Retractable Cord | Provided |
| X-Ray Tube Head | Monoblock Version/ Standard |
| X-Ray Tube | Rotating Anode |
| Collimator | Manaul/Auto/Multi Lead Operated With Beam Diaphragm |
| Tube Stand | Spring Balance/ Counter Balance Mobile (CBM) |
| Power Supply | 230v, AC, Sinngle Phase +-10% 440v AC Three Phase +-10% 50Hz |
It seems like you have provided a set of statements related to X-ray technology. Here is an explanation of what each statement means:
| Business Type | Manufacturer, Exporter, Supplier |
| Model | GRD 20 |
| X Ray Generator | High Frequency 40Khz/ 200Khz |
| Output Power | 20.0 KW |
| Rad. KV | 40-125kV |
| Rad. MA | Upto 300 MA |
| Mas Range | 1 To 200mAs |
| Control Panel | Totally Feather Touch Micro Controller Based |
| Digital Display | KV And MAs |
| Interlocks | Earth Fault, Voltage Error, Rotor Error, KV Error, Fillament Error & Thermal Protection |
| Dual Action Hand Switch With Retractable Cord | Provided |
| X-Ray Tube Head | Monoblock Version/ Standard |
| X-Ray Tube | Rotating Anode |
| Collimator | Manaul/Auto/Multi Lead Operated With Beam Diaphragm |
| Tube Stand | Spring Balance/ Counter Balance Mobile (CBM) |
| Power Supply | 230v, AC, Sinngle Phase +-10% 440v AC Three Phase +-10% 50Hz |